Wenzhou Chima Automatic Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Gong Krystal
  • Company Name : Wenzhou Chima Automatic Technology Co., Ltd.
  • Tel : 86-400-0076866-802
  • Fax : 86-400-0076866
  • Address : Zhejiang,Yueqing,No.23,zhongxin lane,Wengyang Town,Yueqing City,Zhejiang,China
  • Country/Region : China

Anolog Thermostat110v

Anolog Thermostat110v
Product Detailed
Related Categories:Electric Heater Parts
International Standard Electronic Heating,LED turned on while heating,Applied in the auto-control system of space heating.

Thermostat Characteristics:

    Mounted on the surface of the wall indoors    Temperature control range +5/+40°C    Applied in the auto-control system of space heating

    LED turned on while heating    Satisfying the requirements of safety, energy saving and comfort. 

Types Table:

TypesLoad CurrentMethods of Temperature Measurement
A5.16I16AInside Sensor
A5.16D16AOutside&Inside Sensor

Technique Parameters:Voltage: 220VACPower consumption: 5VATemperature control range: 5~40°CTemperature limit range: 25~55°CPower save mode temperature: 5°CTemperature deviation: ±0.5KAmbient temperature: -5~50°CDegree of protection provided by enclosure: IP20

Outer sensor: length of cable 3m

Mounting of Outer Sensor:Please place the casing under the floor with the outer sensor in, the terminal of which should be thickened and placed on the top of the concrete layer. Sensor cable can be extended to 50m with other cables if necessary. If multi-core cable is used as extended cable, extra cable core should not be used for power supply (e.g. power supply for heating cable) for avoiding the interference of voltage signal to the heating thermostat. If there is shielded cable in the extended cable, shielded cable should not be connected to ground but to terminal 7. It is recommended that the extended cable and casing should not be shared with others.

Outer sensor and its resistance:

 Temperature(°C)

Resistance(Ω)

 5 22070
 10 17960
 20 12091
 30 8312
 40 5827

Mounting Location Recommended:The heating thermostat should be mounted on the wall with air flowing freely around.Warning: The mounting location should not be influenced by other heat source (e.g. sunlight), air flow through doors & windows or temperature of outer wall.

Temperature Set:The factory default of temperature control range is +5/+40°C. For convenient adjusting the LED will be turned on while heating. For the first use, please set the thermostat at the highest temperature, when the room or floor temperature approaches the expected, please turn the knob back until the LED is turned off. One or two days after, user could do fine turning if necessary.

Anolog Thermostat110v



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.